This note is to inform vendors of proper use of the data in this folder. ***********************************1228044-05**************************************** 1228044-05 removes U26, and removes R355, and populates R354. This is to allow current 009 PCBs with the GND_SIGNAL isolated net to still be used. 1228044-05 Drawing and data: PCB Q25042-009 BOM1228044revE FCT REV02 VOLGA WET UI ***********************************1228044-05**************************************** ***********************************1228044-06**************************************** 1228044-06 removes R354, and populates U26 and populates R355. This uses corrected 010 PCBs with the GND_SIGNAL correctly tied to GND layer. 1228044-06 Drawing and data: PCB Q25042-010 BOM1228044revF FCT REV02 VOLGA WET UI ***********************************1228044-06****************************************